간접 변환 방식(a-Si)의 디지털 X선 촬영장치 성능평가

Performance evaluation of indirect digital radiography system

초록/요약

In this paper, the indirect conversion method in clinical use of digital radiography system performance was evaluated. In experiments were performed by using an amorphus silicon flat panel detector. The ability of the imaging system to reproduce the measured objects in a natural manner can be characterized by a number of different parameters such as; ESF (Edge spread function), LSF (Line spread function), MTF (Modulation transfer function), NPS (Noise power spectrum), and DQE (Detective quantum efficiency). These parameters can be received for each detector through experimental measurements of a sharp edge. The starting point of the project is the suggestions that are stated in the standard form IEC (62220-1) determination of detective quantum efficiency, which was published by the end of 2003.

more

목차

제 1 장 서 론 1

제 2 장 이론적 배경 3

2.1 디지털 X선 촬영 장치 3

2.1.1 간접 변환 방식(Indirect Conversion Method) 4
2.1.2 직접 변환 방식(Direct Conversion Method) 4

2.2 CsI(Tl) + a-Si 기반 방사선영상 검출기 6

2.2.1 CsI(Tl) 섬광체(Scintillator)의 특징 7
2.2.2 a-Si 광검출 소자의 특징 8

2.3 디지털 X선 촬영 장치의 영상 소프트웨어 9

2.3.1 디지털 X선 촬영 장치의 영상 보정 10
2.3.2 디지털 X선 촬영 장치의 영상 후처리 11

2.4 디지털 X선 촬영 장치의 영상 성능 평가인자 12

2.4.1 공간분해능(Spatial Resolution) 13
2.4.2 대조도(Contrast) 15
2.4.3 잡음(Noise) 15
2.4.4 변조전달함수 (MTF, Modulation Transfer Function) 16
2.4.5 신호 대 잡음비 (SNR, Signal to Noise Ratio) 19
2.4.6 잡음 스펙트럼 (NPS, Noise Power Spectrum) 20
2.4.7 검출양자효율 (DQE, Detective Quantum Efficiency) 21

2.5. IEC 62220-1 23

2.5.1 IEC 62220-1 적용범위 23
2.5.2 운전조건 (Operating Conditions) 24
2.5.3 X선 장비 (X-ray equipment) 24
2.5.4 선질(Radiation quality) 24
2.5.5 시험장비(Test device) 25
2.5.6 구조(Geometry) 26
2.5.7 방사조건(Irradiation conditions) 28
2.5.7.1 일반조건(General conditions) 28
2.5.7.2 시차효과의 예방(Avoidance of lag effects) 29
2.5.7.3 전환기능을 얻기 위한 방사
(Irradiation to obtain the conversion function) 29
2.5.7.4 잡음력 스펙트럼 측정용 방사(Irradiation for
determination of the noise power spectrum) 29
2.5.7.5 방사선 영역에서의 시험 장비 방사
(Irradiation with test device in the beam) 30
2.5.8 미가공 데이터의 보정(Corrections of raw data) 30
2.5.9 검출 양자 효율의 결정
(Determination of the detective quantum efficiency) 30
2.5.9.1 DQE(f)의 정의와 공식 30
2.5.9.2 평가에 사용되는 인자
(Parameters to be used for evaluation) 31
2.5.10 적합성 명세서 형식(Format of conformance statement) 32

제 3 장 연구 재료 및 실험 방법 33

3.1 연구 재료 33

3.1.1 디지털 X선 촬영장치 33
3.1.2 간접 변환 방식의 검출기 33
3.1.3 MTF 측정용 팬텀 34

3.2 실험 방법 35

3.2.1 실험 장비 배치 (geometry) 35
3.2.2 선질의 결정(Determination of radiation quality No.) 36
3.2.2.1 기준 관전압 결정 36
3.2.2.2 기준 관전류량 결정 37
3.2.3 검출기 표면의 air-kerma 측정(Measurement of air-kerma) 37
3.2.4 선형성 측정(Measurement of linearity) 38
3.2.5 NPS 측정(Measurement of NPS) 38
3.2.6 MTF 측정(Measurement of MTF) 40
3.2.7 DQE측정(Measurement of DQE) 41

제 4 장 연구 결과 42

4.1 기준 관전압 결과 42

4.2 선형성 평가 43

4.3 NPS 평가 44

4.4 MTF 평가 47

4.5 DQE 평가 49

제 5 장 결 론 50

제 6 장 참고문헌 52

제 7 장 Abstract 55

감사의 글

more